BibTex Citation Data :
@article{GT4711, author = {Ignatius Christiawan}, title = {PERKUATAN (STRENGTHENING) STRUKTUR KOLOM DENGAN METODA PENAMBAHAN TULANGAN}, journal = {Gema Teknologi}, volume = {16}, number = {3}, year = {2012}, keywords = {}, abstract = { Ignatius Chistiawan , in this paper explain that in the management of buildings, frequent damage to buildings due to the increasing load beyond the load plan. Safety of building users to the dangers of building collapse is the main priority. The addition of load beyond the load on the building plans because of changes in building functions often lead to the collapse of the building. The addition of load beyond the load on the building plans because of changes in building functions often lead to the collapse of buildings. Structural strength e valuation to the condition of existing building is required and w hen it is necessary to give reinforcement to the plate, beams and columns before adding a new load. additional reinforcement is one way of strengthening the column . Research was focused on performance evaluation of structure on existing condition relate at regulation of the Procedure of Concrete Structure Calculation for the SNI 2847-2002. From some previous research, the basics of analysis and design of flexible and practical calculation examples retrofitting columns with the addition of reinforcement can be concluded that this method is easy and practically implemented and can improve the flexural strength of reinforced concrete columns . Keywords : load addition, evaluation, strength, safety. }, issn = {2656-582X}, pages = {135--140} doi = {10.14710/gt.v16i3.4711}, url = {https://ejournal.undip.ac.id/index.php/gema_teknologi/article/view/4711} }
Refworks Citation Data :
Ignatius Chistiawan, in this paper explain that in the management of buildings, frequent damage to buildings due to the increasing load beyond the load plan. Safety of building users to the dangers of building collapse is the main priority.
The addition of load beyond the load on the building plans because of changes in building functions often lead to the collapse of the building. The addition of load beyond the load on the building plans because of changes in building functions often lead to the collapse of buildings. Structural strength evaluation to the condition of existing building is required and when it is necessary to give reinforcement to the plate, beams and columns before adding a new load. additional reinforcement is one way of strengthening the column.
Research was focused on performance evaluation of structure on existing condition relate at regulation of the Procedure of Concrete Structure Calculation for the SNI 2847-2002.
From some previous research, the basics of analysis and design of flexible and practical calculation examples retrofitting columns with the addition of reinforcement can be concluded that this method is easy and practically implemented and can improve the flexural strength of reinforced concrete columns.
Keywords : load addition, evaluation, strength, safety.
Article Metrics:
Last update:
Last update: 2024-12-26 20:16:31
The Authors submitting a manuscript do so on the understanding that if accepted for publication, copyright of the article shall be assigned to Gema Teknologi Journal and Vocational School of Diponegoro University as the publisher of the journal. Copyright encompasses rights to reproduce and deliver the article in all form and media, including reprints, photographs, microfilms, and any other similar reproductions, as well as translations.
Gema Teknologi Journal, Vocational School of Diponegoro University and the Editors make every effort to ensure that no wrong or misleading data, opinions or statements be published in the journal. In any way, the contents of the articles and advertisements published in Gema Teknologi Journal are sole and responsibility of their respective authors and advertisers.