@article{GT8930, author = {Syarif Aripin and Moediyono Moediyono}, title = {APLIKASI PLC SEBAGAI PENGATUR ARAH PUTARAN MOTOR DC UNTUK MENGGERAKAN PMS PADA MINIATUR GARDU INDUK}, journal = {Gema Teknologi}, volume = {17}, number = {3}, year = {2015}, keywords = {}, abstract = { Syarif Aripin, Moediyono , in this paper explain that experiment PLC module is a module that consists of modules and visual experiments. This experimental module consists of PLC (Programmeble Logic Controller) which contained PLC in Central Processor Unit (CPU), memory such as RAM (Radom Access Memory), EPROM (Erasable Programmable Only Memory), EEPROM (Electrical Erasable Programmeble Read Only Memory), input-output module and power supply units (Power supply). PLC is used as props in a series of applications to set the dc motor speed desired by mengguanakan input of the switch. OMRON PLC used is CP1EE with 40 I / O, ie 24 inputs and 16 outputs, PLC is used here as a regulator to enable drivers dc motor is used as a regulator dc motor rotation direction to move pms. In the later rounds measured measurement value is varied. The results of these measurements can be read on the voltmeter and ammeter. Keywords: Driver Motor, DC Motor, Omron PLC CP1E, PMS. }, issn = {2656-582X}, doi = {10.14710/gt.v17i3.8930}, url = {https://ejournal.undip.ac.id/index.php/gema_teknologi/article/view/8930} }
Refworks Citation Data :
Syarif Aripin, Moediyono, in this paper explain that experiment PLC module is a module that consists of modules and visual experiments. This experimental module consists of PLC (Programmeble Logic Controller) which contained PLC in Central Processor Unit (CPU), memory such as RAM (Radom Access Memory), EPROM (Erasable Programmable Only Memory), EEPROM (Electrical Erasable Programmeble Read Only Memory), input-output module and power supply units (Power supply). PLC is used as props in a series of applications to set the dc motor speed desired by mengguanakan input of the switch. OMRON PLC used is CP1EE with 40 I / O, ie 24 inputs and 16 outputs, PLC is used here as a regulator to enable drivers dc motor is used as a regulator dc motor rotation direction to move pms. In the later rounds measured measurement value is varied. The results of these measurements can be read on the voltmeter and ammeter.
Article Metrics:
Last update:
Last update: 2024-11-20 09:43:46
The Authors submitting a manuscript do so on the understanding that if accepted for publication, copyright of the article shall be assigned to Gema Teknologi Journal and Vocational School of Diponegoro University as the publisher of the journal. Copyright encompasses rights to reproduce and deliver the article in all form and media, including reprints, photographs, microfilms, and any other similar reproductions, as well as translations.
Gema Teknologi Journal, Vocational School of Diponegoro University and the Editors make every effort to ensure that no wrong or misleading data, opinions or statements be published in the journal. In any way, the contents of the articles and advertisements published in Gema Teknologi Journal are sole and responsibility of their respective authors and advertisers.