BibTex Citation Data :
@article{GT90243, author = {Rama Alya Rozin Pintaka and Dista Yoel Tadeus}, title = {Rancang Bangun Sistem Monitoring Ketidakseimbangan Pembebanan Trafo Distribusi 3 Phase Menggunakan Arduino Mega Berbasis IoT}, journal = {Gema Teknologi}, volume = {22}, number = {1}, year = {2022}, keywords = {Arduino Mega 2560, Losses, Current, Neutral Current, Load Imbalance, Transformer, PZEM-004T Sensor, ESP-8266 Wemos D1 Mini, ThingSpeak, Inductive Load.}, abstract = { The load current in each phase does not have the same value, and the neutral current does not equal zero, which can result in power losses. This condition is caused by uneven load distribution across each phase during transformer operation, as well as differences in the operating times of consumer loads. Based on this situation, a load imbalance monitoring system was developed. The system utilizes the ESP-8266 Wemos D1 Mini Wi-Fi module to transmit sensor measurement data and provide warnings through the ThingSpeak website when load imbalance exceeds the applicable limit (>25% according to SPLN 12:1978). The data are obtained from measurements using the PZEM-004T sensor, with a measurement error ranging from 0.02–0.05%, and are then processed by an Arduino Mega 2560. When a load imbalance occurs, the microcontroller activates a buzzer and sends a warning notification to Twitter through the ThingSpeak website. Load control is performed manually by simulating different loads on each phase, resulting in the presence of neutral current. }, issn = {2656-582X}, pages = {38--43} doi = {10.14710/gt.v22i1.90243}, url = {https://ejournal.undip.ac.id/index.php/gema_teknologi/article/view/90243} }
Refworks Citation Data :
The load current in each phase does not have the same value, and the neutral current does not equal zero, which can result in power losses. This condition is caused by uneven load distribution across each phase during transformer operation, as well as differences in the operating times of consumer loads. Based on this situation, a load imbalance monitoring system was developed. The system utilizes the ESP-8266 Wemos D1 Mini Wi-Fi module to transmit sensor measurement data and provide warnings through the ThingSpeak website when load imbalance exceeds the applicable limit (>25% according to SPLN 12:1978). The data are obtained from measurements using the PZEM-004T sensor, with a measurement error ranging from 0.02–0.05%, and are then processed by an Arduino Mega 2560. When a load imbalance occurs, the microcontroller activates a buzzer and sends a warning notification to Twitter through the ThingSpeak website. Load control is performed manually by simulating different loads on each phase, resulting in the presence of neutral current.
Article Metrics:
Last update:
Last update: 2026-11-19 19:00:02
The Authors submitting a manuscript do so on the understanding that if accepted for publication, copyright of the article shall be assigned to Gema Teknologi Journal and Vocational School of Diponegoro University as the publisher of the journal. Copyright encompasses rights to reproduce and deliver the article in all form and media, including reprints, photographs, microfilms, and any other similar reproductions, as well as translations.
Gema Teknologi Journal, Vocational School of Diponegoro University and the Editors make every effort to ensure that no wrong or misleading data, opinions or statements be published in the journal. In any way, the contents of the articles and advertisements published in Gema Teknologi Journal are sole and responsibility of their respective authors and advertisers.