BibTex Citation Data :
@article{GT21867, author = {Herdoyo Wirawan and Arkhan Subari}, title = {RANCANG BANGUN DAN MONITORING PENYEARAH DAN ATS (AUTO TRANSFER SWITCH) PADA SISTEM MONITORING SUMBER DC GARDU INDUK BERBASIS ARDUINO MEGA 2560}, journal = {Gema Teknologi}, volume = {19}, number = {2}, year = {2017}, keywords = {automatic transfer switch; rectifier; DC source; voltage sensor;}, abstract = { Herdoyo Wirawan, Arkhan Subari , in this paper explain that the DC source at a PLN substation has a very important role in the smooth operation of the substation itself in a protection and serving the electricity needs of customers. This DC source serves to drive protective equipment, emergency lighting, and others. When the DC source on the receptor is interrupted, the dc source used is a DC source that comes from the battery. When certain conditions cannot guarantee whether the battery capacity is capable of supporting the load borne by the battery, it must always be monitored with a voltage sensor. In order for the protective equipment to continue to work, when the rectifier from the PLN power supply is cut off, a voltage source from 12VDC batteries is used. Switching the voltage source between the rectifier and the battery is done automatically by using the ATS (Automatic Transfer Switch) circuit. When the DC source from the PLN electricity supply will return it will be detected by an optocoupler sensor which later ATS will automatically switch the voltage source again. }, issn = {2656-582X}, pages = {24--29} doi = {10.14710/gt.v19i2.21867}, url = {https://ejournal.undip.ac.id/index.php/gema_teknologi/article/view/21867} }
Refworks Citation Data :
Herdoyo Wirawan, Arkhan Subari, in this paper explain that the DC source at a PLN substation has a very important role in the smooth operation of the substation itself in a protection and serving the electricity needs of customers. This DC source serves to drive protective equipment, emergency lighting, and others.
When the DC source on the receptor is interrupted, the dc source used is a DC source that comes from the battery. When certain conditions cannot guarantee whether the battery capacity is capable of supporting the load borne by the battery, it must always be monitored with a voltage sensor. In order for the protective equipment to continue to work, when the rectifier from the PLN power supply is cut off, a voltage source from 12VDC batteries is used. Switching the voltage source between the rectifier and the battery is done automatically by using the ATS (Automatic Transfer Switch) circuit. When the DC source from the PLN electricity supply will return it will be detected by an optocoupler sensor which later ATS will automatically switch the voltage source again.
Article Metrics:
Last update:
Threadmill-Based Battery Recharging System: Design and Implementation
Last update: 2024-11-15 08:12:55
The Authors submitting a manuscript do so on the understanding that if accepted for publication, copyright of the article shall be assigned to Gema Teknologi Journal and Vocational School of Diponegoro University as the publisher of the journal. Copyright encompasses rights to reproduce and deliver the article in all form and media, including reprints, photographs, microfilms, and any other similar reproductions, as well as translations.
Gema Teknologi Journal, Vocational School of Diponegoro University and the Editors make every effort to ensure that no wrong or misleading data, opinions or statements be published in the journal. In any way, the contents of the articles and advertisements published in Gema Teknologi Journal are sole and responsibility of their respective authors and advertisers.