BibTex Citation Data :
@article{GT8808, author = {Azis Wardana and Arkhan Subari}, title = {PERBANDINGAN PENGARUH PENEMPATAN ARRESTER SEBELUM DAN SESUDAH FCO SEBAGAI PENGAMAN TRANSFORMATOR 3 PHASA TERHADAP GANGGUAN SURJA PETIR DI PENYULANG PANDEAN LAMPER 5 RAYON SEMARANG TIMUR}, journal = {Gema Teknologi}, volume = {18}, number = {1}, year = {2014}, keywords = {}, abstract = { Azis Nurrochma Wardana, Arkhan Subari , in paper comparison of the effect of placement arrester before and after FCO as safety of 3 phase transformator from interruption of lightning at Pandean Lamper 5 Feeder, East Semarang explain that problem of the studied is location of arrester at distribution which have is same function and target but owning location of different arrester. Location of arrester relate to wiring of arrester with transformer and fuse Cut Out (FCO) owning target to give protection at transformer of over voltage. In the last location of this arrester require to study again about its efficacy of its at transformer. Efficacy of pr otection at such transformer is efficacy of passed to protection is transformer by minimizing over voltage that happened at the transformer so that equipments and transformer which its of him do not experience of damage. By considering factor influencing the level of voltage of surge and current of surge that happened at each system, like wiring of arrester, length of wire, apart arrester which is utilized in system location of arrester, steepness of wave come, speed creep waving surge, and Basic InsulationLevel (BIL) equipments, so that is in the final got one of location of correct arrester as 20 kV distribution transformer protection. Keywords: Arrester, Distribution Transformer, Fuse Cut Out, Lightning Surge }, issn = {2656-582X}, pages = {5--8} doi = {10.14710/gt.v18i1.8808}, url = {https://ejournal.undip.ac.id/index.php/gema_teknologi/article/view/8808} }
Refworks Citation Data :
Azis Nurrochma Wardana, Arkhan Subari, in paper comparison of the effect of placement arrester before and after FCO as safety of 3 phase transformator from interruption of lightning at Pandean Lamper 5 Feeder, East Semarang explain that problem of the studied is location of arrester at distribution which have is same function and target but owning location of different arrester. Location of arrester relate to wiring of arrester with transformer and fuse Cut Out (FCO) owning target to give protection at transformer of over voltage. In the last location of this arrester require to study again about its efficacy of its at transformer. Efficacy of pr otection at such transformer is efficacy of passed to protection is transformer by minimizing over voltage that happened at the transformer so that equipments and transformer which its of him do not experience of damage. By considering factor influencing the level of voltage of surge and current of surge that happened at each system, like wiring of arrester, length of wire, apart arrester which is utilized in system location of arrester, steepness of wave come, speed creep waving surge, and Basic InsulationLevel (BIL) equipments, so that is in the final got one of location of correct arrester as 20 kV distribution transformer protection.
Article Metrics:
Last update:
Last update: 2024-11-05 17:54:59
The Authors submitting a manuscript do so on the understanding that if accepted for publication, copyright of the article shall be assigned to Gema Teknologi Journal and Vocational School of Diponegoro University as the publisher of the journal. Copyright encompasses rights to reproduce and deliver the article in all form and media, including reprints, photographs, microfilms, and any other similar reproductions, as well as translations.
Gema Teknologi Journal, Vocational School of Diponegoro University and the Editors make every effort to ensure that no wrong or misleading data, opinions or statements be published in the journal. In any way, the contents of the articles and advertisements published in Gema Teknologi Journal are sole and responsibility of their respective authors and advertisers.