BibTex Citation Data :
@article{GT90271, author = {Aulia Nurul Yunizah and Fakhruddin Mangkusasmito}, title = {Simulasi Manuver Pada Jaringan Tegangan Menengah Penyulang Tanjung Jati B 03 PT PLN (Persero) Berbasis Arduino Mega 2560 Dengan Monitoring VT SCADA 12.1}, journal = {Gema Teknologi}, volume = {21}, number = {3}, year = {2021}, keywords = {Maneuver, PMT, recloser, LBS, SCADA, ETAP simulation}, abstract = { A protection system is necessary in a distribution network to ensure the network remains reliable. The purpose of protection equipment in a distribution network is to minimize damage to the system. In addition, protective equipment is also useful for minimizing the spread of faults so that outages can be limited to smaller areas. Given these functions, network maneuvers are necessary, utilizing protective equipment to prevent faults from spreading further. To facilitate learning about network maneuvers, a maneuver simulation tool was developed for this final project. The results of experiments conducted on this simulation tool showed that the PMT was set to a current of 0.5 A, the recloser was set to a current of 0.5 A, and the LBS was set to a current of 0.4 A. }, issn = {2656-582X}, pages = {125--133} doi = {10.14710/gt.v21i3.90271}, url = {https://ejournal.undip.ac.id/index.php/gema_teknologi/article/view/90271} }
Refworks Citation Data :
A protection system is necessary in a distribution network to ensure the network remains reliable. The purpose of protection equipment in a distribution network is to minimize damage to the system. In addition, protective equipment is also useful for minimizing the spread of faults so that outages can be limited to smaller areas. Given these functions, network maneuvers are necessary, utilizing protective equipment to prevent faults from spreading further. To facilitate learning about network maneuvers, a maneuver simulation tool was developed for this final project. The results of experiments conducted on this simulation tool showed that the PMT was set to a current of 0.5 A, the recloser was set to a current of 0.5 A, and the LBS was set to a current of 0.4 A.
Article Metrics:
Last update:
Last update: 2026-11-17 19:03:31
The Authors submitting a manuscript do so on the understanding that if accepted for publication, copyright of the article shall be assigned to Gema Teknologi Journal and Vocational School of Diponegoro University as the publisher of the journal. Copyright encompasses rights to reproduce and deliver the article in all form and media, including reprints, photographs, microfilms, and any other similar reproductions, as well as translations.
Gema Teknologi Journal, Vocational School of Diponegoro University and the Editors make every effort to ensure that no wrong or misleading data, opinions or statements be published in the journal. In any way, the contents of the articles and advertisements published in Gema Teknologi Journal are sole and responsibility of their respective authors and advertisers.