BibTex Citation Data :
@article{GT21956, author = {Aloisius Dewa and Priyo Sasmoko}, title = {ALAT UKUR TDS (TOTAL DISSOLVED SOLID) AIR GARAM DENGAN RESISTIF SEBAGAI INDIKATOR}, journal = {Gema Teknologi}, volume = {19}, number = {1}, year = {2016}, keywords = {}, abstract = { Aloisius Wisnu Lalita Dewa, Priyo Sasmoko in this paper explain that, physical water quality can be identified in various ways, one of which is measuring the amount of solute called Total Dissolved Solid (TDS). This study aims to design and make a TDS solution by using two electrodes as sensors. These two electrodes flow alternating current and negative values alternately into water. Analog signal in the form of voltage is read by the microcontroller by converting it into a digital signal, then the microcontroller processes the data and displays the TDS value. Tests are carried out by measuring the same solution using TDS meters and salt water TDS. Testing starts from a solution of 175 ppm to 8500 ppm. Making solutions based on TDS meter factory production. The results of salt water TDS measurements showed that the measured tds values increased from 173 ppm to 8007 ppm. Error reading at 8500 ppm, this is because the reading distance of salt water TDS is only up to 8260 ppm. Keywords : TDS, conductivity, electroda, measurement device. References Malvino. 1995. Prinsip-prinsip Elektronkai . Jakarta : Erlangga. Rusmadi, Dedy. 2001. Mengenal Komponen Elektronika. Bandung : Pionir Jaya Sumariyah, Yulianto. T, Priyono J, 2006. Rancang Bangun Sistem Pengukur Konduktivitas Larutan Elektrolit Menggunakan Mikrokontoler AT89C51. Program Studi Fisika Fakultas MIPA Universitas Diponegoro. Semarang. Utomo, D. 2012. Alat pengukur resistansi konduktivitas. dan Total dissolved solids air dengan Teknik dorong-tarik . Program Studi Sistem Komputer. Fakultas Teknik Elektronika dan Komputer. Universitas Kristen Satya Wacana. Salatiga. Wiono.A,Rahmawati. E, 2014. Perancangan Dan Pembuatan Alat Ukur Konduktivitas Larutan Berbasis Mikrokontroler . Program Studi Fisika Fakultas MIPA Universitas Negeri Surabaya. Surabaya }, issn = {2656-582X}, pages = {9--11} doi = {10.14710/gt.v19i1.21956}, url = {https://ejournal.undip.ac.id/index.php/gema_teknologi/article/view/21956} }
Refworks Citation Data :
Aloisius Wisnu Lalita Dewa, Priyo Sasmoko in this paper explain that, physical water quality can be identified in various ways, one of which is measuring the amount of solute called Total Dissolved Solid (TDS). This study aims to design and make a TDS solution by using two electrodes as sensors. These two electrodes flow alternating current and negative values alternately into water. Analog signal in the form of voltage is read by the microcontroller by converting it into a digital signal, then the microcontroller processes the data and displays the TDS value. Tests are carried out by measuring the same solution using TDS meters and salt water TDS. Testing starts from a solution of 175 ppm to 8500 ppm. Making solutions based on TDS meter factory production. The results of salt water TDS measurements showed that the measured tds values increased from 173 ppm to 8007 ppm. Error reading at 8500 ppm, this is because the reading distance of salt water TDS is only up to 8260 ppm.
Keywords : TDS, conductivity, electroda, measurement device.
References
Article Metrics:
Last update:
Last update: 2024-11-14 07:39:39
The Authors submitting a manuscript do so on the understanding that if accepted for publication, copyright of the article shall be assigned to Gema Teknologi Journal and Vocational School of Diponegoro University as the publisher of the journal. Copyright encompasses rights to reproduce and deliver the article in all form and media, including reprints, photographs, microfilms, and any other similar reproductions, as well as translations.
Gema Teknologi Journal, Vocational School of Diponegoro University and the Editors make every effort to ensure that no wrong or misleading data, opinions or statements be published in the journal. In any way, the contents of the articles and advertisements published in Gema Teknologi Journal are sole and responsibility of their respective authors and advertisers.