skip to main content

SIMULASI DAN MONITORING KOORDINASI RECLOSER DAN SSO PADA JARINGAN DISTRIBUSI 20 KV PT. PLN (PERSERO) AREA SEMARANG PENYULANG KALISARI 07 BERBASIS ARDUINO MEGA 2560 DAN VT SCADA 11.2

Hanif Zuraida  -  Teknik Elektro, Sekolah Vokasi, Universitas Diponegoro, Indonesia
*Heru Winarno  -  Teknik Elektro, Sekolah Vokasi, Universitas Diponegoro, Indonesia

Citation Format:
Abstract

 

Hanif Zuraida, Heru Winarno, in this article describes the simulation of protection equipment coordination systems, especially in the recloser and sectionalizer areas. Coordination between protective equipment to improve the network reliability system so that in the event of a disturbance, the area affected by the disturbance does not spread widely. The simulation tool is made using OMRON LY2N 12V relay, ULN2803 relay driver circuit, ZMCT103C current sensor, voltage divider voltage sensor, pull down, 12V 6W lamp as a load and several resistors with different resistivity values as interference. Arduino Mega 2560 is used as the central controller for the entire circuit. After the experiment, the results obtained are when the normal network current at the recloser is 0.86 A and the current at the LBS SSO1 is 0.43. The recloser and LBS SSO1 coordination lies in zone 2 and 3 disturbances. When simulated zone 2 interference, the recloser current rises to 1.28 A, causing reclose / trip to lock out recloser. When the recloser feels a fault current in zone 3 of 1.06 A and LBS SSO1 senses a current of 0.64 A. The recloser as protective equipment will open first within 1000 ms after sensing the disturbance. When the recloser opens, the voltage on the SSO will be 0 volts and the SSO will open within 1000 ms after the current and disturbance requirements are met. Then the recloser will close again after 2000 ms from the open condition.
Fulltext View|Download
Keywords: coordination of recloser and LBS SSO; ZMCT103C sensor; Arduino Mega 2560

Article Metrics:

  1. Saputra, Rian Adhi. 2009. Studi Analisa Koordinasi Sectionalizer Recloser Menggunakan Metode RIA Untuk Peningkatan Keandalan Pada Penyulang Suparma II Di GI Waru. Laporan Penelitian Tidak Diterbitkan. Surabaya: Institut Teknologi Sepuluh Nopember
  2. Pandjaitan, Bonar. 1999. Teknologi Sistem Pengendalian Tenaga Listrik Berbasis Scada. Jakarta: SMTG Desa Putera
  3. Widodo, Sri Thomas. 2002. Elektronika Dasar. Jakarta: Salemba Teknik
  4. Embenesia, 2015. Pull Up dan Pull Down. https://embenesia.wordpress.com/.Diakses tanggal 21 juni 2019 pukul 21.03
  5. Arduino & Genuino Products. Getting Started with the Arduino Ethernet Shield. https://www.arduino.cc/en/Guide/ArduinoEthernetShield. Diakses tanggal 30 Juni 2019 pukul 21.37
  6. O. Cwikowski, M. Barnes, R. Shuttleworth, and B. Chang, Analysis and simulation of the proactive hybrid circuit breaker, in Proceedings of the International Conference on Power Electronics and Drive Systems, 2015
  7. M. Darwish, C. Marouchos, and P. Dimitriadis, Overvoltage protection, in Proceedings - 2016 51st International Universities Power Engineering Conference, UPEC 2016, 2017

Last update:

No citation recorded.

Last update: 2024-04-18 04:25:24

No citation recorded.