BibTex Citation Data :
@article{ROTASI90846, author = {Rusnaldy Rusnaldy}, title = {Pengaruh Bentuk Grip terhadap Linearitas Daerah Elastis Kurva Uji Tarik Logam}, journal = {ROTASI}, volume = {28}, number = {3}, year = {2026}, keywords = {Tensile testing, grip, stress-strain curves, linearity, and slip}, abstract = { Tensile tests conducted previously have occasionally yielded non-linear stress-strain curves within the elastic deformation region. Several factors could be responsible for this, one of which relates to the type of grip employed—specifically, the wedge grips that were being used. Inspection of the grip surfaces revealed that some of the teeth had undergone wear. To improve the tensile test data, new grips—referred to as \"jaw grips\"—were fabricated. Subsequently, tensile tests were performed on four types of materials—AISI 1018 steel, AISI 1045 steel, 6061-T6 aluminum alloy, and C36000 brass—using both types of grips. A numerical analysis using the Finite Element Method (FEM) in ANSYS was also carried out to determine the maximum von Mises stress occurring in the grips, the safety factor, and the potential for slippage during the tensile tests. The results demonstrate that replacing the wedge grips with the new jaw grips produces a linear stress-strain curve in the elastic deformation region. Furthermore, the FEM analysis indicates that the jaw grips result in lower maximum von Mises stress, a higher safety factor, and the elimination of slippage during tensile testing compared to the use of wedge grips. }, issn = {2406-9620}, pages = {1--8} doi = {10.14710/rotasi.28.3.1-8}, url = {https://ejournal.undip.ac.id/index.php/rotasi/article/view/90846} }
Refworks Citation Data :
Tensile tests conducted previously have occasionally yielded non-linear stress-strain curves within the elastic deformation region. Several factors could be responsible for this, one of which relates to the type of grip employed—specifically, the wedge grips that were being used. Inspection of the grip surfaces revealed that some of the teeth had undergone wear. To improve the tensile test data, new grips—referred to as "jaw grips"—were fabricated. Subsequently, tensile tests were performed on four types of materials—AISI 1018 steel, AISI 1045 steel, 6061-T6 aluminum alloy, and C36000 brass—using both types of grips. A numerical analysis using the Finite Element Method (FEM) in ANSYS was also carried out to determine the maximum von Mises stress occurring in the grips, the safety factor, and the potential for slippage during the tensile tests. The results demonstrate that replacing the wedge grips with the new jaw grips produces a linear stress-strain curve in the elastic deformation region. Furthermore, the FEM analysis indicates that the jaw grips result in lower maximum von Mises stress, a higher safety factor, and the elimination of slippage during tensile testing compared to the use of wedge grips.
Article Metrics:
Last update:
Last update: 2026-11-16 14:23:18
Hak Cipta: Penulis memegang hak cipta atas artikel mereka dan memberikan hak publikasi pertama kepada Jurnal Rotasi.
Lisensi Terbitan: Semua artikel disebarluaskan di bawah lisensi Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License (CC BY-NC-SA 4.0), yang mengizinkan pihak lain untuk menyalin, mendistribusikan, menampilkan, serta membuat karya turunan dari artikel ini dengan ketentuan:
Attribution (BY): Wajib memberikan pencantuman kredit/penghargaan yang sesuai kepada penulis asli dan Jurnal Rotasi sebagai penerbit pertama, menyertakan tautan lisensi, dan menunjukkan jika ada perubahan yang dilakukan.
NonCommercial (NC): Karya tidak boleh digunakan untuk tujuan komersial atau mencari keuntungan finansial tanpa izin tertulis dari pemegang hak cipta.
ShareAlike (SA): Jika Anda menggubah, mengubah, atau membuat karya turunan berdasarkan materi ini, Anda harus menyebarluaskan hasil karya tersebut di bawah lisensi yang sama (CC BY-NC-SA 4.0).
Arsip & Retensi: Penulis diizinkan untuk menyebarluaskan dan mengunggah karya mereka secara daring (misalnya di repositori institusi atau situs web pribadi) setelah publikasi, dengan tetap mencantumkan atribusi ke terbitan Jurnal Rotasi.
Penerbit: Departemen Teknik Mesin, Fakultas Teknik, Universitas Diponegoro
Alamat Redaksi: Gedung Administrasi Lantai II Departemen Teknik Mesin Fakultas Teknik Undip Telp.(024)7460059, Facsimile: (024)7460059 ext.102 Email: rotasi@live.undip.ac.id