skip to main content

Reabilitas Daya Dukung Pondasi Tiang Bor Berdasarkan Formula Reese & Wright dan Usulan Load Resistance Factor Design dalam Perencanaan Pondasi Tiang Bor Studi Kasus Proyek Jakarta

*Yudhi Lastiasih  -  Teknik Sipil FTSL Intitut Teknologi Bandung, Indonesia
Masyhur Irsyam  -  Jurusan Teknik Sipil Fakultas Teknik Institut Teknologi Bandung, Indonesia
Indra Djati Sidi  -  Jurusan Teknik Sipil Fakultas Teknik Institut Teknologi Bandung, Indonesia
FX Toha  -  Jurusan Teknik Sipil Fakultas Teknik Institut Teknologi Bandung, Indonesia

Citation Format:
Abstract
Design bored pile foundation often use formulae of Reese and wright (1977) on projects heild in Jakarta. The safety factor often use on the design foundation on project in Jakarta are generally 2 or 3. By using advance First Order Liability Method to analysis design foundation, the result showed that the design was very conservative. Proven by the safety index for this design is 2.68 where’s the equivalent of failure probably 3.72 x 10-3, this result is less than requirement of failure probability 1 x 10-2. Lastiasih (2012) propose the use of multiple safety factors by applying Load Resistance Factor Design (LRFD) in accordance with the design of building age so as not to use single safety factor again. Further more the design of bored pile foundation become more efficient.
Fulltext View|Download
Keywords: Safety index; First order reliability method; LRFD

Article Metrics:

Last update:

No citation recorded.

Last update: 2024-12-21 07:49:05

No citation recorded.