Pinch analysis for a sugar plant production capacity 4000 TCD has been carried out to reduce its energy consumptions. The plant has ten evaporators that can be configured to several multiple effect evaporators. It has been running with five-effect evaporator (quintuple) scheme. To maximize energy utilization within the plant, three multiple effect evaporator schemes were evaluated. They are triple effect evaporator, quadruple effect evaporator, and quintuple effect evaporator as the benchmark. The result shows that the quintuple effect evaporator yields the highest energy efficiency by about 10%. Options to achieve such target is to use low pressure steam only for the first effect and to use steam bleeding from the first effect to heat a tertiary juice heater. With this proposed scenario, sugar dryer, wash water RVF unit and wash water HGF unit no longer need external steam for its operation.

Fulltext View|Download

Article Metrics:

Last update:

  1. Analisis Pindah Panas Konduksi dan Konveksi pada Heat Exchanger Evaporator Efek Ganda pada Pengolahan Nira Tebu

    Khoirul Anam As Syukri, Dony Perdana, Moch. Izza Maulana Sulthon, Sumardi Hadi Sumarlan. Jurnal Ilmiah Rekayasa Pertanian dan Biosistem, 11 (2), 2023. doi: 10.29303/jrpb.v11i2.221

Last update: 2024-11-17 10:48:20