BibTex Citation Data :
@article{Transmisi3743, author = {Abdul Syakur dan Galuh Susilowati dan Satyagraha AK dan A. Parlindungan Siregar}, title = {PENGUJIAN TAN δ PADA KABEL TEGANGAN MENENGAH}, journal = {Transmisi: Jurnal Ilmiah Teknik Elektro}, volume = {11}, number = {2}, year = {2012}, keywords = {}, abstract = { High voltage testing have purpose to investigate the electrical properties of dielectric related with isolation quality of power equipment during pre-installed or in operation time to prevent equipment losses. Isolation quality is important rule to determine electrical equipment quality, especially for power transmission and distribution. Cable, one of this electrical equipment will be investigated in this research using the high voltage testing with the tan δ method. We use the high voltage laboratory of PT. PLN (Persero) Pusat Penelitian dan Pengembangan Ketenagalistrikan, Jakarta, for that kind of testing. There are 6 different middle voltage cable types under the test, as the result the measured tan δ values not extend the maximum value, as IEC 60502-2 (2005-2) standard, 40 (x10 -4 ), for each cable. According to that measurement, all of six cable types passed the tan δ test. Keywords : tan δ testing, cable, isolation quality }, issn = {2407-6422}, pages = {107--112} doi = {10.12777/transmisi.11.2.107-112}, url = {https://ejournal.undip.ac.id/index.php/transmisi/article/view/3743} }
Refworks Citation Data :
High voltage testing have purpose to investigate the electrical properties of dielectric related with isolation quality of power equipment during pre-installed or in operation time to prevent equipment losses. Isolation quality is important rule to determine electrical equipment quality, especially for power transmission and distribution. Cable, one of this electrical equipment will be investigated in this research using the high voltage testing with the tan δ method. We use the high voltage laboratory of PT. PLN (Persero) Pusat Penelitian dan Pengembangan Ketenagalistrikan, Jakarta, for that kind of testing. There are 6 different middle voltage cable types under the test, as the result the measured tan δ values not extend the maximum value, as IEC 60502-2 (2005-2) standard, 40 (x10-4), for each cable. According to that measurement, all of six cable types passed the tan δ test.
Keywords: tan δ testing, cable, isolation quality
Article Metrics:
Last update:
Last update: 2024-12-26 05:06:41
Transmisi: Jurnal Ilmiah Teknik Elektro dan Departemen Teknik Elektro, Universitas Diponegoro dan Editor berusaha keras untuk memastikan bahwa tidak ada data, pendapat, atau pernyataan yang salah atau menyesatkan dipublikasikan di jurnal. Dengan cara apa pun, isi artikel dan iklan yang diterbitkan dalam Transmisi: Jurnal Ilmiah Teknik Elektro adalah tanggung jawab tunggal dan eksklusif masing-masing penulis dan pengiklan.
Formulir Transfer Hak Cipta dapat diunduh di sini: [Formulir Transfer Hak Cipta Transmisi]. Formulir hak cipta harus ditandatangani dan dikirim ke Editor dalam bentuk surat asli, dokumen pindaian atau faks:
Dr. Munawar Riyadi (Ketua Editor)Departemen Teknik Elektro, Universitas Diponegoro, IndonesiaJl. Prof. Sudharto, Tembalang, Semarang 50275 IndonesiaTelepon/Facs: 62-24-7460057Email: transmisi@elektro.undip.ac.id