BibTex Citation Data :
@article{Transmisi3746, author = {Iwan Setiawan dan Budi Setiyono dan Tri Susilo}, title = {Hasil Uji Kalibrasi Sensor Accelerometer ADXL335}, journal = {Transmisi: Jurnal Ilmiah Teknik Elektro}, volume = {11}, number = {3}, year = {2012}, keywords = {}, abstract = { Accelerometer is a sensor that can measure acceleration of object. This sensor can be used for till sensing detection, 3D game interface, computer’s mouse, and vehicle navigation system. Operating of this sensor need a good calibration to get parameters which determines the acceleration. This paper present result of calibration of 3 Axis ADXL335 accelerometer. Calibration of this sensor consist of 3 step testing on every axis of this sensor, sensor’s natural characteristic testing, ZeroG voltage testing, and sensor’s sensitivity testing. The result of testing ZeroG voltage and sensitivity must be compare with information from datasheet. From this testing can be concluded that the ADXL335 accelerometer has responsive output. Percentage of deviation standard is 0.257397% and the minimum is 0%. The value of ZeroG voltage from testing are 1,637390 volt for X axis, 1,638319 volt for Y axis, dan 1,736877 volt for Z axis. And the sensitivity are 0,3096 V/g for X axis, 0,3296925 V/g for Y axis, Z axis is 0,3103370 V/g. Keywords: Accelerometer, accelereration, calibration, ZeroG voltage, sensitivity. }, issn = {2407-6422}, pages = {118--122} doi = {10.12777/transmisi.11.3.118-122}, url = {https://ejournal.undip.ac.id/index.php/transmisi/article/view/3746} }
Refworks Citation Data :
Accelerometer is a sensor that can measure acceleration of object. This sensor can be used for till sensing detection, 3D game interface, computer’s mouse, and vehicle navigation system. Operating of this sensor need a good calibration to get parameters which determines the acceleration. This paper present result of calibration of 3 Axis ADXL335 accelerometer. Calibration of this sensor consist of 3 step testing on every axis of this sensor, sensor’s natural characteristic testing, ZeroG voltage testing, and sensor’s sensitivity testing. The result of testing ZeroG voltage and sensitivity must be compare with information from datasheet. From this testing can be concluded that the ADXL335 accelerometer has responsive output. Percentage of deviation standard is 0.257397% and the minimum is 0%. The value of ZeroG voltage from testing are 1,637390 volt for X axis, 1,638319 volt for Y axis, dan 1,736877 volt for Z axis. And the sensitivity are 0,3096 V/g for X axis, 0,3296925 V/g for Y axis, Z axis is 0,3103370 V/g.
Keywords: Accelerometer, accelereration, calibration, ZeroG voltage, sensitivity.
Article Metrics:
Last update:
Last update: 2024-11-13 01:39:24
Transmisi: Jurnal Ilmiah Teknik Elektro dan Departemen Teknik Elektro, Universitas Diponegoro dan Editor berusaha keras untuk memastikan bahwa tidak ada data, pendapat, atau pernyataan yang salah atau menyesatkan dipublikasikan di jurnal. Dengan cara apa pun, isi artikel dan iklan yang diterbitkan dalam Transmisi: Jurnal Ilmiah Teknik Elektro adalah tanggung jawab tunggal dan eksklusif masing-masing penulis dan pengiklan.
Formulir Transfer Hak Cipta dapat diunduh di sini: [Formulir Transfer Hak Cipta Transmisi]. Formulir hak cipta harus ditandatangani dan dikirim ke Editor dalam bentuk surat asli, dokumen pindaian atau faks:
Dr. Munawar Riyadi (Ketua Editor)Departemen Teknik Elektro, Universitas Diponegoro, IndonesiaJl. Prof. Sudharto, Tembalang, Semarang 50275 IndonesiaTelepon/Facs: 62-24-7460057Email: transmisi@elektro.undip.ac.id