skip to main content

PENGOLAHAN LINDI DENGAN OZON DAN PROSES OKSIDASI LANJUT BERBASIS OZON

*Mohamad Rangga Sururi  -  Jurusan Teknik Lingkungan, Fakultas Teknik Sipil dan Perencanaan, Institut Teknologi Nasional, Indonesia
Siti Ainun Saleh  -  Jurusan Teknik Lingkungan, Fakultas Teknik Sipil dan Perencanaan, Institut Teknologi Nasional, Indonesia
Amalia Krisna  -  Jurusan Teknik Lingkungan, Fakultas Teknik Sipil dan Perencanaan, Institut Teknologi Nasional

Citation Format:
Abstract

Limbah industri tekstil di area pinggir kota Surabaya mempunyai karakteristik perbandingan COD dan BOD = 5.57. Limbah jenis ini sulit untuk dibiodegradasi. Studi ini mempelajari tekonologi elektrokoagulasi untuk mengolah limbah tekstil dengan menurunkan intensitas warna, Total Suspended Solid (TSS) dan Chemical Oxygen Demand (COD). Percobaan batch pada suhu kamar dilakukan untuk mempelajari pengaruh pH, jarak elektroda terhadap penurunan warna,TSS dan COD dan membandingkan biaya operasinya jika menggunakan pengolahan kimia.Effisiensi penurunan tertinggi untuk warna (91.96%),  TSS (49.17%), dan COD (29.67%) terjadi pada pH awal 4.0 dan jarak elektroda 2 cm dengan  elektroda Al/Al. Waktu optimum penurunan intensitas warna dalah 10 menit. Laju penurunan COD adalah : -dC/dt = 0.0053 C +0.056 , dengan C adalah konsentrasi COD. Jumlah sludge yang dihasilkan daripengolahan elektrokoagulasi  3.4 % lebih kecil dibandingkan menggunakan bahan kimia. Biaya yang digunakan untuk pengolahan dengan elektrokoagulasi 52.35 % lebih murah dibandingkan jika menggunakan koagulasi dengan bahan kimia ( tawas).

Kata kunci : elektrokoagulasi, penurunan warna, penurunan TSS, laju degradasi COD, imbah tekstil

Abstract

Waste water from textile industry which is located in one suburb of Surabaya city as characteristic which the ratio of COD to BOD was 5.57. This type of waste water is difficult to be biodegraded. This study investigated elektrokoagulasi technology to treat textile waste water by removing color, total suspended solid, and Chemical Oxygen Demand. Batch experiment at room temperature was carried out to study the effect of pH, electrode distance for color, TSS and COD removal. This study also tried to compare the operation cost between elektrokoagulasi and chemical processes. The best removal efficiencies by Al electrodes was 91.96 % for color, 49.17 % for TSS and 29.67 % for COD which were under initial pH 4.0 and electrodes distance 2 cm. The optimum operation time for color removal was  found 10 minutes.The COD degradation rate was - dC/dt = 0.0053 C +0.056, with C= COD concentration. Sludge result from elektrokoagulasi was 3.4 % less than that by chemical treatment.The operation cost for elektrokoagulasi is 52.35 % less than that for chemical coagulation.


Fulltext View|Download
Keywords: leacheate, Advance Oxidation Process, ozone decomposition rate, OH radical, removal efficiency
Funding: Direktoral Jendral Perguruan Tinggi

Article Metrics:

Last update:

  1. Leachate Treatment from Sarimukti Landfill Using Ozone with Sludge from Water Treatment Plant as a Catalyst

    Muhammad Yudha Ramdhani, M. Rangga Sururi, Siti Ainun, D. Roosmini, K. Pribadi, B. Sugeng, I.K. Hadihardaja. MATEC Web of Conferences, 147 , 2018. doi: 10.1051/matecconf/201814704006

Last update: 2024-11-08 21:43:47

No citation recorded.