1Analytical Chemistry Department, Politeknik AKA Bogor, Jl. Pangeran Sogiri No.283, RT.05/RW.11, Tanah Baru, Kec. Bogor Utara, Kota Bogor 16154, Indonesia
2Industrial Waste Treatment Department, Polytechnic of AKA Bogor, Jl. Pangeran Sogiri No.283, RT.05/RW.11, Tanah Baru, Kec. Bogor Utara, Kota Bogor 16154, Indonesia
3Environment Monitoring Department, PT. Jababeka Infrastruktur, Bekasi, Indonesia
BibTex Citation Data :
@article{JKSA82822, author = {Junjunan Muhammad Syukur and Erna Styani and Muhammad Yanwar Prasetyo}, title = {Method Evaluation for Chemical Oxygen Demand (COD) in Wastewater Treatment Plant Samples from an Industrial Estate using Closed Reflux Colorimetry}, journal = {Jurnal Kimia Sains dan Aplikasi}, volume = {29}, number = {6}, year = {2026}, keywords = {COD; Environmental monitoring; Uncertainty; Industrial estate}, abstract = {This study presents the verification of the APHA Standard Method 5220 D for determining chemical oxygen demand (COD) in wastewater using a spectroscopic closed-reflux colorimetric system. Both the low range (LR: 0–90 mg O 2 /L) and high range (HR: 90–700 mg O 2 /L) methods were verified to ensure their suitability for wastewater monitoring in the industrial estate, with the LR method applied to effluent samples and the HR method applied to influent samples. Method performance was evaluated using linearity, sensitivity, limit of detection (LOD), limit of quantification (LOQ), limit of linearity (LOL), precision, accuracy, and measurement uncertainty for both LR and HR COD levels. The calibration curves exhibited excellent linearity, with coefficients of determination (R 2 ) of 0.9991 (LR) and 0.9996 (HR). The LOD (3S yx /b) and LOQ (10S yx /b) values were 3.34 and 11.14 mg O 2 /L for LR, and 15.48 and 51.59 mg O 2 /L for HR, respectively. Precision testing produced %RSD values of 2.88% (LR) and 1.37% (HR), both meeting acceptance criteria based on ⅔ CV Horwitz. Accuracy evaluation using potassium hydrogen phthalate (KHP) standards yielded recoveries of 97.50–106.02% (LR) and 98.83–102.92% (HR), consistent with Association of Official Analytical Chemists (AOAC) requirements. Measurement uncertainty was assessed by combining contributions from calibration, precision, accuracy, and instrumental factors, resulting in expanded uncertainties of ±3.83 mg O 2 /L for LR and ±13.87 mg O 2 /L for HR (k = 2). The findings confirm that the method is reliable and suitable for routine COD analysis in wastewater monitoring.}, issn = {2597-9914}, pages = {388--395} doi = {10.14710/jksa.29.6.388-395}, url = {https://ejournal.undip.ac.id/index.php/ksa/article/view/82822} }
Refworks Citation Data :
Note: This article has supplementary file(s).
Article Metrics:
Last update:
Last update: 2026-09-15 02:10:41
As an article writer, the author has the right to use their article for various purposes, including use by institutions that employ the author or institutions that provide funding for the research. These author rights are granted without special permission.
Authors who publish a paper in JKSA have broad rights to use their work for teaching and scientific purposes without the need to request permission, including: (i) teaching in the author's class or institution; (ii) presenting the work at meetings or conferences and distributing copies to participants; (iii) using the work in training conducted by the author or the author's institution; (iv) distributing copies to colleagues for research purposes; (v) using the work in the compilation of subsequent works by the author; (vi) including the work in a thesis or dissertation; (vii) reusing part of the article in another work, with appropriate citation; (viii) preparing derivative works, with appropriate citation; and (ix) voluntarily posting the work on open websites operated by the author or the author's institution for scientific purposes, in accordance with the CC BY-SA License.
Authors and readers may copy and redistribute the material in any medium or format, and may remix, transform, and build upon the material for any purpose, provided that they give appropriate credit by citing the article or its content, provide a link to the license, and indicate if changes were made.
The authors submitting a manuscript do so on the understanding that, if accepted for publication, the copyright of the article shall be assigned to Jurnal Kimia Sains dan Aplikasi (JKSA). Copyright encompasses the rights to reproduce and distribute the article in all forms and media, including reprints, photographs, microfilms, and any other similar reproductions, as well as translations.
Reproducing any part of this journal, storing it in a database, or transmitting it in any form or medium is permitted without written permission from JKSA. However, the original source must be properly cited in accordance with academic conventions.
JKSA, the Chemistry Department of Diponegoro University, and the Editor make every effort to ensure that no inaccurate, false, or misleading data, opinions, or statements are published in JKSA. However, the content of each article is the sole and exclusive responsibility of its authors.
The Copyright Transfer Form can be downloaded here: [Copyright Transfer Form - Indonesian] [Copyright Transfer Form - English]. The copyright form should bear the authors' original signatures and be sent to the Editor as a printed document, a scanned document sent via email, or by fax.
Prof. Adi Darmawan, Ph.D (Editor in Chief)
Editor in chief of Jurnal Kimia Sains dan Aplikasi (JKSA)
Chemistry Department, Faculty of Sciences and Mathematics, Diponegoro University
Visitor: View My Stats
Jurnal Kimia Sains dan Aplikasi is indexed in:
This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.