1Analytical Chemistry Department, Politeknik AKA Bogor, Jl. Pangeran Sogiri No.283, RT.05/RW.11, Tanah Baru, Kec. Bogor Utara, Kota Bogor 16154, Indonesia
2Industrial Waste Treatment Department, Polytechnic of AKA Bogor, Jl. Pangeran Sogiri No.283, RT.05/RW.11, Tanah Baru, Kec. Bogor Utara, Kota Bogor 16154, Indonesia
3Environment Monitoring Department, PT. Jababeka Infrastruktur, Bekasi, Indonesia
BibTex Citation Data :
@article{JKSA82822, author = {Junjunan Muhammad Syukur and Erna Styani and Muhammad Yanwar Prasetyo}, title = {Method Evaluation for Chemical Oxygen Demand (COD) in Wastewater Treatment Plant Samples from an Industrial Estate using Closed Reflux Colorimetry}, journal = {Jurnal Kimia Sains dan Aplikasi}, volume = {29}, number = {6}, year = {2026}, keywords = {COD; Environmental monitoring; Uncertainty; Industrial estate}, abstract = {This study presents the verification of the APHA Standard Method 5220 D for determining chemical oxygen demand (COD) in wastewater using a spectroscopic closed-reflux colorimetric system. Both the low range (LR: 0–90 mg O 2 /L) and high range (HR: 90–700 mg O 2 /L) methods were verified to ensure their suitability for wastewater monitoring in the industrial estate, with the LR method applied to effluent samples and the HR method applied to influent samples. Method performance was evaluated using linearity, sensitivity, limit of detection (LOD), limit of quantification (LOQ), limit of linearity (LOL), precision, accuracy, and measurement uncertainty for both LR and HR COD levels. The calibration curves exhibited excellent linearity, with coefficients of determination (R 2 ) of 0.9991 (LR) and 0.9996 (HR). The LOD (3S yx /b) and LOQ (10S yx /b) values were 3.34 and 11.14 mg O 2 /L for LR, and 15.48 and 51.59 mg O 2 /L for HR, respectively. Precision testing produced %RSD values of 2.88% (LR) and 1.37% (HR), both meeting acceptance criteria based on ⅔ CV Horwitz. Accuracy evaluation using potassium hydrogen phthalate (KHP) standards yielded recoveries of 97.50–106.02% (LR) and 98.83–102.92% (HR), consistent with Association of Official Analytical Chemists (AOAC) requirements. Measurement uncertainty was assessed by combining contributions from calibration, precision, accuracy, and instrumental factors, resulting in expanded uncertainties of ±3.83 mg O 2 /L for LR and ±13.87 mg O 2 /L for HR (k = 2). The findings confirm that the method is reliable and suitable for routine COD analysis in wastewater monitoring.}, issn = {2597-9914}, pages = {388--395} doi = {10.14710/jksa.29.6.388-395}, url = {https://ejournal.undip.ac.id/index.php/ksa/article/view/82822} }
Refworks Citation Data :
Note: This article has supplementary file(s).
Article Metrics:
Last update:
Last update: 2026-08-02 10:34:12
As an article writer, the author has the right to use their articles for various purposes, including use by institutions that employ authors or institutions that provide funding for research. Author rights are granted without special permission.
Author who publishes a paper at JKSA has the broad right to use their work for teaching and scientific purposes without the need to ask permission, including: used for (i) teaching in the author's class or institution, (ii) presentation at meetings or conferences and distributing copies to participants ; (iii) training conducted by the author or author's institution; (iv) distribution to colleagues for research use; (v) use in the compilation of subsequent authors' works; (vi) inclusion in a thesis or dissertation; (vi) reuse of part of the article in another work (with citation); (vii) preparation of derivative works (with citation); (viii) voluntary posting on open websites operated by authors or author institutions for scientific purposes (follow the CC BY-SA License).
Authors and readers can copy and redistribute material in any media or format, and mix, modify, and build material for any purpose but they must provide appropriate credit (provide article citation or content), providing links to the license, and indicate if there are changes.
The authors submitting a manuscript do so on the understanding that if accepted for publication, copyright of the article shall be assigned to Jurnal Kimia Sains dan Aplikasi (JKSA). Copyright encompasses rights to reproduce and deliver the article in all form and media, including reprints, photographs, microfilms and any other similar reproductions, as well as translations.
Reproduce any part of this journal, its storage in the database or its transmission by all forms or media is permitted does not need for written permission from JKSA. However, it should be cited as an honor in academic manners
JKSA and the Chemistry Department of Diponegoro University and the Editor make every effort to ensure that there are no data, opinions, or false or misleading statements published in JKSA. However, the content of the article is the sole and exclusive responsibility of each author.
The Copyright Transfer Form can be downloaded here: [Copyright Transfer Form - Indonesian] [Copyright Transfer Form - English]. The copyright form should be signed originally and send to the Editor in the form of printed letters, scanned documents sent via email or fax.
Adi Darmawan, Ph.D (Editor in Chief)
Editor in chief of Jurnal Kimia Sains dan Aplikasi (JKSA)
Chemistry Department, Faculty of Sciences and Mathematics, Diponegoro University
Visitor: View My Stats
Jurnal Kimia Sains dan Aplikasi is indexed in:
This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.