1Electric Power Company Elektroprivreda of Bosnia and Herzegovina – Sarajevo, Department for Strategic Development, SARAJEVO, Bosnia and Herzegovina
2Faculty of Electrical Engineering, Sarajevo University, Department for Power Engineering, SARAJEVO, Bosnia and Herzegovina
BibTex Citation Data :
@article{IJRED4100, author = {A Merzic and M. Music and M Rascic}, title = {First Aspect of Conventional Power System Assessment for High Wind Power Plants Penetration}, journal = {International Journal of Renewable Energy Development}, volume = {1}, number = {3}, year = {2012}, keywords = {}, abstract = { Most power systems in underdeveloped and developing countries are based on conventional power plants, mainly \"slow-response\" thermal power plants and a certain number of hydro power plants; characterized by inflexible generating portfolios and traditionally designed to meet own electricity needs. Taking into account operational capabilities of conventional power systems, their development planning will face problems with integration of notable amounts of installed capacities in wind power plants (WPP). This is what highlights the purpose of this work and in that sense, here, possible variations of simulated output power from WPP in the 10 minute and hourly time interval, which need to be balanced, are investigated, presented and discussed. Comparative calculations for the amount of installed power in WPP that can be integrated into a certain power system, according to available secondary balancing power amounts, in case of concentrated and dispersed future WPP are given. The stated has been done using a part of the power system of Bosnia and Herzegovina. In the considered example, by planned geographically distributed WPP construction, even up to cca. 74% more in installed power of WPP can be integrated into the power system than in case of geographically concentrated WPP construction, for the same available amount of (secondary) balancing power. These calculations have shown a significant benefit of planned, geographically distributed WPP construction, as an important recommendation for the development planning of conventional power systems, with limited balancing options. Keywords: balancing reserves, geographical dispersion, output power variations }, pages = {107--113} doi = {10.14710/ijred.1.3.107-113}, url = {https://ejournal.undip.ac.id/index.php/ijred/article/view/4100} }
Refworks Citation Data :
Most power systems in underdeveloped and developing countries are based on conventional power plants, mainly "slow-response" thermal power plants and a certain number of hydro power plants; characterized by inflexible generating portfolios and traditionally designed to meet own electricity needs. Taking into account operational capabilities of conventional power systems, their development planning will face problems with integration of notable amounts of installed capacities in wind power plants (WPP). This is what highlights the purpose of this work and in that sense, here, possible variations of simulated output power from WPP in the 10 minute and hourly time interval, which need to be balanced, are investigated, presented and discussed. Comparative calculations for the amount of installed power in WPP that can be integrated into a certain power system, according to available secondary balancing power amounts, in case of concentrated and dispersed future WPP are given. The stated has been done using a part of the power system of Bosnia and Herzegovina. In the considered example, by planned geographically distributed WPP construction, even up to cca. 74% more in installed power of WPP can be integrated into the power system than in case of geographically concentrated WPP construction, for the same available amount of (secondary) balancing power. These calculations have shown a significant benefit of planned, geographically distributed WPP construction, as an important recommendation for the development planning of conventional power systems, with limited balancing options.
Keywords: balancing reserves, geographical dispersion, output power variations
Article Metrics:
Last update:
Power utility generation portfolio optimization as function of specific RES and decarbonisation targets – EPBiH case study
Application of the Maximum Entropy Method for Determining a Sensitive Distribution in the Renewable Energy Systems
A complementary hybrid system for electricity generation based on solar and wind energy taking into account local consumption - Case study
Last update: 2024-11-20 22:40:08
Power utility generation portfolio optimization as function of specific RES and decarbonisation targets - EPBiH case study
This journal provides immediate open access to its content on the principle that making research freely available to the public supports a greater global exchange of knowledge. Articles are freely available to both subscribers and the wider public with permitted reuse.
All articles published Open Access will be immediately and permanently free for everyone to read and download. We are continuously working with our author communities to select the best choice of license options: Creative Commons Attribution-ShareAlike (CC BY-SA). Authors and readers can copy and redistribute the material in any medium or format, as well as remix, transform, and build upon the material for any purpose, even commercially, but they must give appropriate credit (cite to the article or content), provide a link to the license, and indicate if changes were made. If you remix, transform, or build upon the material, you must distribute your contributions under the same license as the original.
International Journal of Renewable Energy Development (ISSN:2252-4940) published by CBIORE is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.