skip to main content

Study of The Feasibility of Minimarkets in Pontianak Cities Based on the Microbiological Quality of Air In Relation to the Physical Condition of the Room

Siti Almira Rahminda  -  Universitas Tanjungpura, Indonesia
*Jumiati Jumiati  -  Universitas Tanjungpura, Indonesia
Aini Sulastri  -  Universitas Tanjungpura, Indonesia

Citation Format:
Abstract

Indoor air quality affects human health and productivity. The presence of microorganisms in indoor air is influenced by physical parameters of the space, activities within the space, building factors, ventilation systems, and human maintenance and care. This study aims to assess air quality and analyze the difference in the number of bacteria between minimarkets and the relationship test with their influencing factors. The study used a cross sectional method with 4 minimarket samples, 2 AC and 2 non-AC. Airborne bacterial colony counts were measured using a passive method with blood agar media, a contact time of 15 minutes, and 3 days of repetition. The average value of airborne bacterial colony counts in non-air-conditioned minimarkets (294.3 CFU/) was lower than in air-conditioned minimarkets (531.8 CFU/). The Rank Spearman correlation test results indicated that there was no significant relationship between airborne bacterial colony counts and temperature (p=0.498), humidity (p=0.089), light intensity (p=0.948), and visitor count (p=0.481). All studied minimarkets met the microbiological air quality, population density, and air circulation standards, but not all met the standards for room temperature, humidity, and light intensity based on the quality standards of the Indonesian Ministry of Health Number 1405/MENKES/SK/XI/2002.

Fulltext View|Download
Keywords: Air quality; airbone bacterial; minimarkets; physical condition

Article Metrics:

  1. Afla, R.A., 2019. Analisis Kualitas Udara Mikrobiologis Parameter Bakteri dan Jamur di Ruang Rawat Inap Rumah Sakit (Studi Kasus : Gedung A Rumah Sakit Umum Pusat Nasional (RSUPN) DR. Cipto Mangunkusumo). Universitas Indonesia, Depok
  2. Arief Faturrahman, M., Kurniatuhadi, R., 2019. Deteksi Keberadaan Bakteri Staphylococcus di Udara Dalam Ruangan Pasar Tradisional Kota Pontianak. Protobiot 8, 30–34
  3. Ariyadi, T., 2009. Pengaruh Sinar Ultra Violet Terhadap Pertumbuhan Bakteri Bacillus sp. Sebagai Bakteri Kontaminan. Kesehatan 2
  4. A’yun, I.Q., Umaroh, R., 2023. Polusi Udara dalam Ruangan dan Kondisi Kesehatan: Analisis Rumah Tangga Indonesia. Jurnal Ekonomi dan Pembangunan Indonesia 23, 16–26
  5. Cahyani, V.D., 2016. Kualitas Bakteriologis Udara Dalam Ruang Perawatan Inap Rsud H. Padjonga Dg. Ngalle Kab. Takalar
  6. Cahyaningrum Amelia Yasmine, 2019. Air Quality Analysis Of Microbiological Bacterial And Fungal Parameters In The Clinical Building (Case Study: Klinik Satelit Building, Universitas Indonesia). Depok
  7. Cintya Dewi, W., Raharjo, M., Endah Wahyuningsih, N., Kesehatan Masyarakat Universitas Diponegoro Jl Sudarto No, F., Kota Semarang Jawa Tengah Indonesia, T., 2021. Literature Review: Link Between Space Air Quality and Health In Terference In Workers. Jurnal Kesehatan Masyarakat 8
  8. Dwi Astuti, N., Hastutiningrum*, S., Sudarsono, S., 2022. Analisis Kualitas Udara Pada Rumah Warga Terhadap Parameter Bakteri dan Jamur. Jurnal Teknologi 15, 166–170
  9. Emdiyono, S.V., Triyantoro, B., 2018. Pengaruh Pemberian Karbol Sebagai Desinfektan Terhadap Jumlah Angka Kuman Pada Lantai Ruang Parikesit Kelas III Rumah Sakit TK III.04.06.1 Wijayakusuma Purwokerto Tahun 2017. Keslingmas 37, 405–534
  10. Fajarwati, D., 2020. Perhitungan Koloni Bakteri Pada Filter AC (Air Conditioner) dan Udara Dalam Ruang Tunggu Pelayanan Medis. Bandung
  11. Gita C., U., Vecky C., P., Abdul H., J.O., 2022. Indoor Air Quality Monitoring System. Teknik Informatika 17, 93–104
  12. KEPALA BADAN PENGAWAS OBAT DAN MAKANAN, 2021. Peraturan Badan Pengawas Obat dan Makanan Nomor 21 Tahun 2021 Tentang Penerapan Sistem Jaminan Keamanan dan Mutu Pangan Olahan Di Sarana Peredaran
  13. Kusumawardhani, C., Gunawan, A.T., Cahyono, T., Jurusan, ), Lingkungan, K., Kesehatan, P., Semarang, K., 2018. Faktor Lingkungan Fisik yang Berhubungan Dengan Angka Kuman Udara di Ruang Rawat Inap Kelas I, II, dan III RST Wijayakusuma Purwokerto Tahun 2018. Keslingmas 38, 124–243
  14. Lestari, P.M., Supandi, Ani, P., 2019. Pembuatan Karbol Sebagai Desinfektan Lantai. SOLMA 8, 193
  15. Lestiani, D.P., Tunggul Pawenang, E., 2018. Lingungan Fisik yang Mempengaruhi Keberadaan Kapang Aspergillus sp dalam Ruang Perpustakaan. HIGEIA 2
  16. Mayasari, A., Zulkarnain, Agrina, S., 2019. Analisis Kualitas Fisik Udara Terhadap Kualitas Fisik Udara Rumah Sakit. Ilmu Lingkungan
  17. Menteri Kesehatan Republik Indonesia, 2002. Keputusan Menteri Kesehatan Republik Indonesia Nomor 1405/MENKES/SK/XI/2002 Tentang Persyaratan Kesehatan Lingkungan Kerja Perkantoran dan Industri
  18. Ningtyas, S.A., 2019. Analisis Kualitas Udara Mikrobiologis Dalam Ruang Perpustakaan Crystal Of Knowledge, Universitas Indonesia, Depok. Universitas Indonesia, Depok
  19. Prajawanti, N.L., Tri, C., Asep, T.G., 2019. Efektivitas Shokivi Desinfection Terhadap Penurunan Angka Kuman Udara Pada Ruang Kelas Gedung R2 Lantai 2 Kampus 7 Poltekkes Kemenkes Semarang Tahun 2018. Buletin Keslingmas 38, 17–28
  20. Pudjadi, E., Suciyani, R., Sahira, I.G., Pikoli, M.R., 2016. Kualitas Mikrobiologis Udara di Salah Satu Pusat Perbelanjaan di Jakarta Selatan. AL-Kauniyah: Jurnal Biologi 8
  21. Putra1, I., Ikhtiar2, M., Emelda3, A., 2018. Analisis Mikroorganisme Udara terhadap Gangguan Kesehatan dalam Ruangan Administrasi Gedung Menara UMI Makassar. Windowof Health : Jurnal Kesehatan 1
  22. Sari, I.V., 2018. Analisis Kualitas Udara Mikrobiologis Pada Gedung S Fakultas Teknik Universitas Indonesia. Universitas Indonesia, Depok
  23. Sukmawaty, E., Manyullei, S., Dwi Cahyani, V., Biologi, J., Sains, F., Teknologi, D., Makassar, A., Masyarakat, F.K., 2017. Kualitas Bakteriologis Udara Dalam Ruang Perawatan VIP Anak RSUD H. Padjonga Daeng Ngalle Kabupaten Takalar. In: Seminar Nasional Biology for Life. Gowa, pp. 38–43
  24. Swandi, F., 2021. Analisis Kandungan Jumlah Bakteri di Udara dalam Ruang Kerja Institusi Pendidikan X di Kota Padang. Universitas Andalas, Padang
  25. Walid, A., Novitasari, N., Wardany, K., 2019. Studi Morfologi Koloni Bakteri Udara Di Lingkungan Fakultas Tarbiyah Dan Tadris Institut Agama Islam Negeri Bengkulu. Jurnal IPA & Pembelajaran IPA 3, 10–14

Last update:

No citation recorded.

Last update: 2024-12-02 08:17:01

No citation recorded.